Glaucoma and optic nerve
How fast is my RNFL or GCIPL thickness changing?
Enter serial OCT thickness values for one measurement to see the trend over time, or the change from first to last scan when there are fewer than five scans over two years.
Each test date is converted to years from the first test. The trend is an ordinary least-squares line of the result against time. Its 95% confidence interval uses the standard error of the slope (residual variance with n − 2 degrees of freedom) and the two-sided Student t value. The trend is shown only with at least 5 included tests spanning at least 2 years; shorter series show the change from the first to the last test.
Keep RNFL, GCIPL and GCC as separate series, and global and sector values separate. These layers thin slowly with age, scan quality and segmentation can shift values, and very thin layers reach a floor where further loss is hard to measure. Your eye doctor interprets the trend with your visual fields and any treatment changes.
For information only. These tools explain numbers and do not replace an eye examination or your eye doctor’s advice. Values you enter stay in your browser.